Tel: +49 (0) 3877 567460   Mail: info@prignitz-mst.de

 

Galaxy of customized solutions

Pressure Sensors for Hazardous areas (Explosion protection)

 

 

PMP-S111-Exi

Intrinsically safe pressure transducer
OPTIMIZED FOR: High pressure, fast temperature changes, aggressive media
PRESSURE-RANGE: 3 – 2.000 bar
MEMBRANE: Steel 17-4PH
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference, Absolute
CERTIFICATIONS:  CSA, ATEX
Used technology:
TFT
Downloads
OPTIMIZED FOR: High pressure, fast temperature changes, aggressive media
PRESSURE-RANGE: 3 – 2.000 bar
MEMBRANE: Steel 17-4PH
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference, Absolute
CERTIFICATIONS: CSA, ATEX
Used technologies
TFT
Downloads
PMP-S100-Exi (example)

PMP-S111-ExnA

Non-sparking pressure transmitter
OPTIMIZED FOR: High pressure, fast temperature changes, aggressive media
PRESSURE-RANGE: 3 – 2.000 bar
MEMBRANE: Steel 17-4PH
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference, Absolute
CERTIFICATIONS: CSA
Used technology:
TFT
Downloads
OPTIMIZED FOR: High pressure, fast temperature changes, aggressive media
PRESSURE-RANGE: 3 – 2.000 bar
MEMBRANE: Steel 17-4PH
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference, Absolute
CERTIFICATIONS: CSA
Used technologies
TFT
Downloads

PMP-S122-ExnA

Non-sparking pressure transmitter
OPTIMIZED FOR: High pressure, aggressive media like Hydrogen
PRESSURE-RANGE: 4 – 1.000 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference
CERTIFICATIONS: CSA
Used technology:
P2P
Downloads
OPTIMIZED FOR: High pressure, aggressive media like Hydrogen
PRESSURE-RANGE: 4 – 1.000 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference
CERTIFICATIONS: CSA
Used technologies
P2P
Downloads

PMP-S122-Exi

Intrinsically safe pressure transducer
OPTIMIZED FOR: High pressure, aggressive media like Hydrogen
PRESSURE-RANGE: 4 – 1.000 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference
CERTIFICATIONS: CSA, ATEX, EC79
 
Used technology:
P2P
Downloads
OPTIMIZED FOR: High pressure, aggressive media like Hydrogen
PRESSURE-RANGE: 4 – 1.000 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference
CERTIFICATIONS: CSA, ATEX, EC79
 
Used technologies
P2P
Downloads

PMP-S122.04-ExD

Explosion Proof / Flameproof Enclosure Pressure Transducer

 

OPTIMIZED FOR: High pressure, aggressive media like Hydrogen
PRESSURE-RANGE: 4 – 1.000 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference
CERTIFICATIONS: CSA 

 
Used technology:
P2P
Downloads
OPTIMIZED FOR: High pressure, aggressive media like Hydrogen
PRESSURE-RANGE: 10 – 1.000 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference
CERTIFICATIONS: CSA
 
Used technologies
P2P
Downloads

PMP-S131-Exi

Intrinsically safe pressure transducer
OPTIMIZED FOR: Low pressure, aggressive media
PRESSURE-RANGE: 60 mbar – 10 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference, Absolute
CERTIFICATIONS: CSA, ATEX
Used technology:
PMI
Downloads
OPTIMIZED FOR: Low pressure, aggressive media
PRESSURE-RANGE: 60 mbar – 10 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference, Absolute
CERTIFICATIONS: CSA, ATEX
Used technologies
PMI
Downloads

PMP-C111-Exi

Intrinsically safe pressure transducer
OPTIMIZED FOR: configurable online, high pressure, fast temperature changes, aggressive medias
PRESSURE-RANGE: 3 – 2.000 bar
MEMBRANE: Steel 17-4PH
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference, Absolute
CERTIFICATIONS: CSA, ATEX
Used technology:
TFT
Downloads
OPTIMIZED FOR: configurable online, high pressure, fast temperature changes, aggressive medias
PRESSURE-RANGE: 3 – 2.000 bar
MEMBRANE: Steel 17-4PH
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference, Absolute
CERTIFICATIONS: CSA, ATEX
Used technologies
TFT
Downloads

PMP-C122-Exi

Intrinsically safe pressure transducer
OPTIMIZED FOR: configurable online, high pressure, aggressive media like Hydrogen
PRESSURE-RANGE: 4 – 1.000 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference
CERTIFICATIONS: CSA, ATEX, EC79
 
Used technology:
P2P
Downloads
OPTIMIZED FOR: configurable online, high pressure, aggressive media like Hydrogen
PRESSURE-RANGE: 4 – 1.000 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference
CERTIFICATIONS: CSA, ATEX, EC79
 
Used technologies
P2P
Downloads

PMP-C122.04-ExD

Explosion Proof / Flameproof Enclosure Pressure Transducer

 

OPTIMIZED FOR: configurable online, high pressure, aggressive media like Hydrogen
PRESSURE-RANGE: 4 – 1.000bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference
CERTIFICATIONS: CSA 
 
Used technology:
P2P
Downloads
OPTIMIZED FOR: configurable online, high pressure, aggressive media like Hydrogen
PRESSURE-RANGE: 10 – 1.000bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference
CERTIFICATIONS: CSA
 
Used technologies
P2P
Downloads

PMP-C131-Exi

Intrinsically safe pressure transducer
OPTIMIZED FOR: configurable online, low pressure, aggressive media
PRESSURE-RANGE: 20 mbar – 10 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference, Absolute
CERTIFICATIONS: CSA, ATEX
Used technology:
PMI
Downloads
OPTIMIZED FOR: configurable online, low pressure, aggressive media
PRESSURE-RANGE: 20 mbar – 10 bar
MEMBRANE: Steel 316L
CELL CONSTRUCTION TYPE: with membrane inside
TYPE OF PRESSURE: Gauge, Sealed reference, Absolute
CERTIFICATIONS: CSA, ATEX
Used technologies
PMI
Downloads

Do you want us to contact you back within 24 hours?

Fill out the form below:

6 + 4 =

Telefon: +49 (0) 38 77 / 5 67 46-0

Fax: +49 (0) 38 77 / 5 67 46-18

Mail: info@prignitz-mst.de

Contact us and we will offer you a custom solution for your business.

©  PRIGNITZ Mikrosystemtechnik GmbH 2024

All rights reserved. / Alle Rechte vorbehalten.